ASTM D6132 PDF

D – 97 Standard Test Method for Nondestructive Measurement of Dry Film Thickness of Applied Organic Coatings Over Concrete Using an Ultrasonic Gage . Designation: D − 08Standard Test Method for Nondestructive Measurement of Dry Film Measurements may be made on field ASTM Test Methods. Designation: D − Standard Test Method for. Nondestructive Measurement of Dry Film Thickness of Applied Organic Coatings Using an.

Author: Kiran Zuktilar
Country: Armenia
Language: English (Spanish)
Genre: Automotive
Published (Last): 13 April 2010
Pages: 238
PDF File Size: 2.22 Mb
ePub File Size: 10.31 Mb
ISBN: 551-4-53209-610-5
Downloads: 28811
Price: Free* [*Free Regsitration Required]
Uploader: Kazram

Link to Active This link will always route to the current Active version of the standard. No other units of measurement are included in this standard. Each of eight laboratories tested seven different coated panels using two types of instrumentation. Precision and Bias4 A thickness range of 0. Some instruments have the ability to detect and measure the individual layer thicknesses in a multi-layer system. Approved July 1, Summ Summary ary of Test Test Method 3.

ASTM D6132-08.pdf

UV cured coating on hickory Panel 2: Water is ideal for smooth, thin coatings. These types of gages can accurately measure the dry film thickness of organic coatings on a variety of substrates such as concrete, wood, wallboard, plastic, fiber composites and metal. We need your help! No other units of measurement are included in this standard. We need your help to maintenance this website.

ASTM D6132 – 13(2017)

Originally approved in Referenced Documents purchase separately The documents listed below are referenced within the subject standard d1632 are not provided as part of the standard. Referenc Referenced ed Documents Documents 2. Measurements may be made on field structures, on commercially manufactured products, or on laboratory test specimens. Last previously edition approved in as D — All laboratories reported two replicate test results for every panel with each instrument.

  ASKEP UVEITIS PDF

A number in paren parenthese thesess indicates the year of last reappr reapproval. Therefore the reference standard should be smooth. Other liquids such as liquid soap may be used. While this is a destructive test method, it will provide an alternative test method to ensure measurements made in accordance with this test method are in the correct range.

For best accuracy, each instrument should be checked against a known thickness of the particular coating being measured and adjusted if necessary.

Please help us to share our service with your friends. Permission rights to photocopy the standard may also be secured from the ASTM website www.

The instrument must be placed directly on the coating surface to take a reading. Current edition approved July 1, Some instruments have the ability to detect and measure the individual asmt thicknesses in a multi-layer system.

ASTM Dpdf – Free Download PDF

We are a non-profit group that run this website to share documents. The instrument may allow a user adjustment to prevent this.

Select the method most appropriate for the material being tested. In addition to potential performance deficiencies, it is uneconomical to apply more material than necessary when coating large areas such as floors and walls. Coatings must be applied within certain minimum and astmm thickness tolerances in order that they can fulfill their intended function.

  BLAH BLAH BLAH GERSHWIN PDF

The instrument’s ability to detect a distinct interface between the coating and the substrate may be impeded if the coating and the substrate are of similar composition, density or attenuation or if the coating is non-homogeneous. For rough coatings, a glycol gel is best, provided it is not a contaminant for the coating to be measured. These seven coated panels were described as the following: A rough surface has a tendency to scatter the ultrasonic pulse and odd readings may occur occasionally.

Hold the probe steady during the measurement. The travel time is converted into a thickness reading. Historical Version s – view previous versions of standard.

Please fill this form, we will try to respond as soon as possible. Thank you for interesting in our services. Please copy and paste this embed script to where you want to embed Embed Script. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

To be able to compare results obtained by different operators, it is essential to measure film thickness carefully. Size px x x x x